| Brand Name: | Weiaipu |
| Model Number: | VIP4‑1A‑06(B041Q0832) |
| MOQ: | 120PCS |
| Price: | 6-8USD |
| Packaging Details: | Carton |
| Payment Terms: | T/T |
The VIP4‑1A‑06(B041Q0832) compact chassis‑mount EMI power filter is a practical retrofit solution for existing electronic equipment as well as new hardware development. Rated 6A RMS for 115/250VAC 50/60Hz single‑phase mains, this single‑stage LC filter utilizes common‑mode choke together with X and Y capacitors to mitigate power‑line common‑mode and differential‑mode conducted interference.
Featuring ultra‑low leakage current characteristics, it prevents ground leakage exceedance when retrofitting legacy devices. Its slim physical footprint enables installation inside crowded cabinets where standard‑size filters cannot fit. High insulation resistance and wide operating temperature ensure reliable performance in on‑site industrial environments.
‑ Suitable both for new‑equipment design and on‑site retrofit / EMC upgrade of existing machinery
‑ 6A RMS rated current, works with global 115/250VAC 50/60Hz single‑phase power supplies
‑ Ultra‑low leakage current (Max 0.3mA@115VAC/60Hz; Max 0.6mA@250VAC/50Hz), avoids ground‑leakage alarm risks during equipment modification
‑ Single‑stage LC topology, delivers effective suppression for power‑line common‑mode and differential‑mode conducted noise
‑ Slim compact metal housing, fits cramped cabinet space where conventional EMI filters cannot be assembled
‑ Insulation resistance ≥100 MΩ @500VDC, guarantees electrical safety for long‑term field operation
‑ Operating temperature: ‑25℃ ~ +100℃, adapts to fluctuating temperature conditions of workshop cabinet environment
‑ On‑site EMC retrofit and noise‑reconstruction upgrade for legacy industrial equipment
‑ Cabinet renovation projects with limited internal installation space
‑ Retrofitting old test instruments and lab devices to pass updated EMC compliance requirements
‑ Refitting commercial self‑service terminals and HMI touch panels for export market access
‑ System‑integration projects where ground leakage current must be strictly controlled
‑ On‑site debugging for machinery suffering from power‑line conducted interference
‑ Compact control cabinet renovation for factory automation production lines
‑ Secondary modification of finished devices for cross‑border sales certification demands
| Item | Specification |
|---|---|
| Rated Voltage | 115 / 250 VAC |
| Rated Current | 6 A RMS Max @115VAC;
|
| Operating Frequency | 50 / 60 Hz |
| Leakage Current (Line‑to‑Ground) | Max 0.3 mA @115VAC / 60 Hz
|
| Insulation Resistance | ≥ 100 MΩ @500 VDC (Any input / output to ground) |
| Operating Temperature Range | ‑25 °C ~ +100 °C |
| Insertion Loss | Reference data under 50‑Ω test system
|
| Insertion Loss | Tested under 50‑Ohm system (data for reference only) |
Q1: What safety and environmental certifications does VIP4‑1A‑06(B041Q0832) have?
A1: VIP4‑1A‑06(B041Q0832) is certified with CE, RoHS and REACH, meeting EU environmental and safety requirements.
Q2: What are voltage, current, temperature & leakage current specs of VIP4‑1A‑06(B041Q0832)?
A2: Rated voltage: 115/250VAC; Rated current: 6A RMS Max; Operating frequency: 50/60Hz; Operating temperature range: ‑25°C ~ +100°C. Max leakage current: 0.3 mA @115VAC/60Hz, 0.6 mA @250VAC/50Hz.
Q3: What's its hi‑pot standard? Mount type & EMI suppression effect?
A3: Insulation resistance ≥100 MΩ @500VDC (Input / Output to Ground). High‑potential withstand test runs for 1 minute. It is compact metal‑cased chassis‑mount type. Adopts single‑stage LC topology with common‑mode inductor, Cx and Cy capacitors, suppressing both common‑mode and differential‑mode conducted noise for EMC compliance. Insertion loss data is measured under 50‑Ohm system for reference only.
Q4: Do you offer free EMC pre‑test & model selection guide? Can you support EMI rectification for inverters and servo equipment?
A4: Free EMC pre‑test and filter model‑selection guidance are available. We provide professional EMC debugging and EMI rectification solutions for inverters, servo systems and other industrial devices.
Q5: What is the recommended wire cross‑section for VIP4‑1A‑06(B041Q0832)? Can it suppress high‑frequency interference from servo drives?
A5: The matching wire shall satisfy 6A current‑carrying capacity. Its internal LC filter circuit can effectively attenuate high‑frequency EMI noise generated by servo drives. Actual performance is subject to real‑world installation and system impedance.
| Brand Name: | Weiaipu |
| Model Number: | VIP4‑1A‑06(B041Q0832) |
| MOQ: | 120PCS |
| Price: | 6-8USD |
| Packaging Details: | Carton |
| Payment Terms: | T/T |
The VIP4‑1A‑06(B041Q0832) compact chassis‑mount EMI power filter is a practical retrofit solution for existing electronic equipment as well as new hardware development. Rated 6A RMS for 115/250VAC 50/60Hz single‑phase mains, this single‑stage LC filter utilizes common‑mode choke together with X and Y capacitors to mitigate power‑line common‑mode and differential‑mode conducted interference.
Featuring ultra‑low leakage current characteristics, it prevents ground leakage exceedance when retrofitting legacy devices. Its slim physical footprint enables installation inside crowded cabinets where standard‑size filters cannot fit. High insulation resistance and wide operating temperature ensure reliable performance in on‑site industrial environments.
‑ Suitable both for new‑equipment design and on‑site retrofit / EMC upgrade of existing machinery
‑ 6A RMS rated current, works with global 115/250VAC 50/60Hz single‑phase power supplies
‑ Ultra‑low leakage current (Max 0.3mA@115VAC/60Hz; Max 0.6mA@250VAC/50Hz), avoids ground‑leakage alarm risks during equipment modification
‑ Single‑stage LC topology, delivers effective suppression for power‑line common‑mode and differential‑mode conducted noise
‑ Slim compact metal housing, fits cramped cabinet space where conventional EMI filters cannot be assembled
‑ Insulation resistance ≥100 MΩ @500VDC, guarantees electrical safety for long‑term field operation
‑ Operating temperature: ‑25℃ ~ +100℃, adapts to fluctuating temperature conditions of workshop cabinet environment
‑ On‑site EMC retrofit and noise‑reconstruction upgrade for legacy industrial equipment
‑ Cabinet renovation projects with limited internal installation space
‑ Retrofitting old test instruments and lab devices to pass updated EMC compliance requirements
‑ Refitting commercial self‑service terminals and HMI touch panels for export market access
‑ System‑integration projects where ground leakage current must be strictly controlled
‑ On‑site debugging for machinery suffering from power‑line conducted interference
‑ Compact control cabinet renovation for factory automation production lines
‑ Secondary modification of finished devices for cross‑border sales certification demands
| Item | Specification |
|---|---|
| Rated Voltage | 115 / 250 VAC |
| Rated Current | 6 A RMS Max @115VAC;
|
| Operating Frequency | 50 / 60 Hz |
| Leakage Current (Line‑to‑Ground) | Max 0.3 mA @115VAC / 60 Hz
|
| Insulation Resistance | ≥ 100 MΩ @500 VDC (Any input / output to ground) |
| Operating Temperature Range | ‑25 °C ~ +100 °C |
| Insertion Loss | Reference data under 50‑Ω test system
|
| Insertion Loss | Tested under 50‑Ohm system (data for reference only) |
Q1: What safety and environmental certifications does VIP4‑1A‑06(B041Q0832) have?
A1: VIP4‑1A‑06(B041Q0832) is certified with CE, RoHS and REACH, meeting EU environmental and safety requirements.
Q2: What are voltage, current, temperature & leakage current specs of VIP4‑1A‑06(B041Q0832)?
A2: Rated voltage: 115/250VAC; Rated current: 6A RMS Max; Operating frequency: 50/60Hz; Operating temperature range: ‑25°C ~ +100°C. Max leakage current: 0.3 mA @115VAC/60Hz, 0.6 mA @250VAC/50Hz.
Q3: What's its hi‑pot standard? Mount type & EMI suppression effect?
A3: Insulation resistance ≥100 MΩ @500VDC (Input / Output to Ground). High‑potential withstand test runs for 1 minute. It is compact metal‑cased chassis‑mount type. Adopts single‑stage LC topology with common‑mode inductor, Cx and Cy capacitors, suppressing both common‑mode and differential‑mode conducted noise for EMC compliance. Insertion loss data is measured under 50‑Ohm system for reference only.
Q4: Do you offer free EMC pre‑test & model selection guide? Can you support EMI rectification for inverters and servo equipment?
A4: Free EMC pre‑test and filter model‑selection guidance are available. We provide professional EMC debugging and EMI rectification solutions for inverters, servo systems and other industrial devices.
Q5: What is the recommended wire cross‑section for VIP4‑1A‑06(B041Q0832)? Can it suppress high‑frequency interference from servo drives?
A5: The matching wire shall satisfy 6A current‑carrying capacity. Its internal LC filter circuit can effectively attenuate high‑frequency EMI noise generated by servo drives. Actual performance is subject to real‑world installation and system impedance.