logo
Good price  online

products details

Home > Products >
EMC EMI Filter
>
VIIP Original VIP4‑2B‑10(10307) EMI Power Line Filter 10A 250VAC Noise Suppressor For Communication Electronics

VIIP Original VIP4‑2B‑10(10307) EMI Power Line Filter 10A 250VAC Noise Suppressor For Communication Electronics

Brand Name: Weiaipu
Model Number: VIP4-2B-10(10307)
MOQ: 120
Price: 5USD
Packaging Details: neutral
Payment Terms: T/T
Detail Information
Certification:
CB UL CQC RoHS REACH
Current Rating:
10A RMS Max
Operating Frequency:
50/60Hz
Line To Ground:
2000 VAC
Line To Line:
500 VDC
Temperature Range:
-25°C~+100°C
Voltage Rating:
115/250VAC
Supply Ability:
30K/MONTH
Highlight:

EMI power line filter 10A 250VAC

,

noise suppressor for communication electronics

,

EMC EMI filter with warranty

Product Description

Product Introduction

The VIP4‑2B‑10 (10307) is a high-quality single-phase double-stage EMI power filter with a 10A continuous current rating, suitable for 115VAC and 250VAC global AC power grids at 50Hz and 60Hz frequencies. Adopting an upgraded dual-stage circuit design, the product offers excellent noise attenuation ability, efficiently suppressing both common-mode and differential-mode high-frequency electromagnetic interference on power lines. The filter complies with strict industrial safety standards, featuring 2000VAC line-to-ground withstand voltage and insulation resistance beyond 100MΩ under 500VDC testing conditions. Equipped with durable solder terminals and supporting a wide temperature range of -25℃ to +100℃, it maintains stable and reliable filtering performance in complex and variable working environments. It effectively protects precision electronic circuits from grid electromagnetic interference and helps end equipment fully meet international EMC certification requirements.
VIIP Original VIP4‑2B‑10(10307) EMI Power Line Filter 10A 250VAC Noise Suppressor For Communication Electronics

Application Scope & Usage

This industrial EMI filter is specially developed to solve conducted electromagnetic interference problems on AC power input circuits. It achieves bidirectional noise isolation: it isolates external grid high-frequency interference to avoid equipment malfunction, and restrains internal electromagnetic noise from being transmitted back to the public power grid. It is widely applicable to industrial control systems, automated production devices, CNC machine tools, precision testing and measurement instruments, communication equipment, switching power supplies, medical auxiliary facilities and high-end household electrical products. Installed at the AC input end of electrical and electronic equipment, it effectively enhances the whole system’s anti-interference performance, ensures stable operation, and supports finished products in passing official EMC compliance tests.
VIIP Original VIP4‑2B‑10(10307) EMI Power Line Filter 10A 250VAC Noise Suppressor For Communication Electronics

FAQ

Q1: Does the EMI filter produce leakage current during operation?

A1: All standard EMI power filters contain built-in Y capacitors, which will generate tiny leakage current during normal operation. This is a normal physical phenomenon for EMC filtering designs. The leakage current of this model is kept within a safe and reasonable range, which will not affect the normal use of equipment or cause safety hazards under standard grounding conditions.

Q2: What is the correct installation position for an EMI filter?

A2: The EMI filter must be installed as close as possible to the equipment’s AC power input terminal. Shorten the input wiring as much as possible and keep the filter’s input cables and output cables completely separated. Avoid crossing or parallel wiring of input and output lines, which can prevent secondary interference and maximize the filtering effect.

Q3: Can the EMI filter be used for DC power supply devices?

A3: This series is a professional AC EMI filter, specially designed for 50/60Hz AC power systems. It cannot be applied to DC power circuits. Using AC filters on DC equipment will fail to achieve filtering effects and may even cause abnormal operation or component damage. Please select a dedicated DC EMI filter for DC scenarios.

Q4: What environmental factors will affect the service performance of EMI filters?

A4: Long-term high-temperature operation, humid environment, severe vibration and dusty working conditions will all affect the stability and service life of EMI filters. It is recommended to install the filter in a dry, ventilated and heat-dissipating environment, avoid over-temperature and damp exposure, and ensure long-term stable working performance.

Q5: Do I need to replace the EMI filter regularly?

A5: EMI filters have no fixed replacement cycle. With standard installation and rated load operation, they can work stably for many years. Regular inspection is recommended. If aging, abnormal heating, increased noise or poor anti-interference effect occurs, the filter should be checked or replaced in time to ensure continuous EMC compliance.

Good price  online

Products Details

Home > Products >
EMC EMI Filter
>
VIIP Original VIP4‑2B‑10(10307) EMI Power Line Filter 10A 250VAC Noise Suppressor For Communication Electronics

VIIP Original VIP4‑2B‑10(10307) EMI Power Line Filter 10A 250VAC Noise Suppressor For Communication Electronics

Brand Name: Weiaipu
Model Number: VIP4-2B-10(10307)
MOQ: 120
Price: 5USD
Packaging Details: neutral
Payment Terms: T/T
Detail Information
Brand Name:
Weiaipu
Certification:
CB UL CQC RoHS REACH
Model Number:
VIP4-2B-10(10307)
Current Rating:
10A RMS Max
Operating Frequency:
50/60Hz
Line To Ground:
2000 VAC
Line To Line:
500 VDC
Temperature Range:
-25°C~+100°C
Voltage Rating:
115/250VAC
Minimum Order Quantity:
120
Price:
5USD
Packaging Details:
neutral
Delivery Time:
31DAY
Payment Terms:
T/T
Supply Ability:
30K/MONTH
Highlight:

EMI power line filter 10A 250VAC

,

noise suppressor for communication electronics

,

EMC EMI filter with warranty

Product Description

Product Introduction

The VIP4‑2B‑10 (10307) is a high-quality single-phase double-stage EMI power filter with a 10A continuous current rating, suitable for 115VAC and 250VAC global AC power grids at 50Hz and 60Hz frequencies. Adopting an upgraded dual-stage circuit design, the product offers excellent noise attenuation ability, efficiently suppressing both common-mode and differential-mode high-frequency electromagnetic interference on power lines. The filter complies with strict industrial safety standards, featuring 2000VAC line-to-ground withstand voltage and insulation resistance beyond 100MΩ under 500VDC testing conditions. Equipped with durable solder terminals and supporting a wide temperature range of -25℃ to +100℃, it maintains stable and reliable filtering performance in complex and variable working environments. It effectively protects precision electronic circuits from grid electromagnetic interference and helps end equipment fully meet international EMC certification requirements.
VIIP Original VIP4‑2B‑10(10307) EMI Power Line Filter 10A 250VAC Noise Suppressor For Communication Electronics

Application Scope & Usage

This industrial EMI filter is specially developed to solve conducted electromagnetic interference problems on AC power input circuits. It achieves bidirectional noise isolation: it isolates external grid high-frequency interference to avoid equipment malfunction, and restrains internal electromagnetic noise from being transmitted back to the public power grid. It is widely applicable to industrial control systems, automated production devices, CNC machine tools, precision testing and measurement instruments, communication equipment, switching power supplies, medical auxiliary facilities and high-end household electrical products. Installed at the AC input end of electrical and electronic equipment, it effectively enhances the whole system’s anti-interference performance, ensures stable operation, and supports finished products in passing official EMC compliance tests.
VIIP Original VIP4‑2B‑10(10307) EMI Power Line Filter 10A 250VAC Noise Suppressor For Communication Electronics

FAQ

Q1: Does the EMI filter produce leakage current during operation?

A1: All standard EMI power filters contain built-in Y capacitors, which will generate tiny leakage current during normal operation. This is a normal physical phenomenon for EMC filtering designs. The leakage current of this model is kept within a safe and reasonable range, which will not affect the normal use of equipment or cause safety hazards under standard grounding conditions.

Q2: What is the correct installation position for an EMI filter?

A2: The EMI filter must be installed as close as possible to the equipment’s AC power input terminal. Shorten the input wiring as much as possible and keep the filter’s input cables and output cables completely separated. Avoid crossing or parallel wiring of input and output lines, which can prevent secondary interference and maximize the filtering effect.

Q3: Can the EMI filter be used for DC power supply devices?

A3: This series is a professional AC EMI filter, specially designed for 50/60Hz AC power systems. It cannot be applied to DC power circuits. Using AC filters on DC equipment will fail to achieve filtering effects and may even cause abnormal operation or component damage. Please select a dedicated DC EMI filter for DC scenarios.

Q4: What environmental factors will affect the service performance of EMI filters?

A4: Long-term high-temperature operation, humid environment, severe vibration and dusty working conditions will all affect the stability and service life of EMI filters. It is recommended to install the filter in a dry, ventilated and heat-dissipating environment, avoid over-temperature and damp exposure, and ensure long-term stable working performance.

Q5: Do I need to replace the EMI filter regularly?

A5: EMI filters have no fixed replacement cycle. With standard installation and rated load operation, they can work stably for many years. Regular inspection is recommended. If aging, abnormal heating, increased noise or poor anti-interference effect occurs, the filter should be checked or replaced in time to ensure continuous EMC compliance.