EMC Case Study: Conducted Emissions Fix for Fitness Equipment

2026-04-07

Product: Fitness Equipment

Standard: EN 55032

Issue: Conducted emissions (Average values above limit below 1 MHz)


Initial Findings

  • Filter 0607 already installed
  • Swapped power board and control board — no improvement
  • Breakthrough: Disconnected earth ground → emissions disappeared

Root Cause:

Noise was coupling onto the ground line and radiating back into the measurement.


The Solution

Extended the ground cable and added a Mn-Zn ferrite core (VMETG-025015015-100):

Configuration Result
Mn-Zn, 4 turns ✅ Pass with margin
Other ferrite types Suboptimal
Fewer turns Insufficient attenuation

Final fix: Mn-Zn ferrite, 4 turns on extended ground line.